COMMERCIAL SPECIFICATION SHEET
PROPERTY TEST METHOD MINIMUM ROLL / AVERAGE VALUE
GRAB TENSILE, LBS ASTM-D-4632 60 LBS
GRAB ELONGATION % ASTM-D-4632 20/25%
MULLEN BURST, PSI ASTM-D-3786 165
PUNCTURE, LBS ASTM-D-4833 30
TRAPEZODAL TEAR, LBS ASTM-D-4533 30 LBS
UV RESISTENCE, %SR ASTM-D-4355 50% @ 500 HRS
AOS, US SIEVE # ASTM-D-4751 40
PERMITTIVITY, (1/SEC) ASTM-D-4491 .20 (S-1)
GAL/MIN/SQ.FT 15 GAL/MIN/FT2



DOT FABRIC
PROPERTY TEST METHOD MINIMUM ROLL / AVERAGE VALUE
MD GRAB TENSILE, LBS ASTM-D-4632 209 LBS
TD GRAB TENSILE, LBS ASTM-D-4632 172 LBS
MD GRAB ELONGATION % ASTM-D-4632 21%
TD GRAB ELONGATION % ASTM-D-4632 27%
MULLEN BURST, PSI ASTM-D-3786 310
MD TRAPAZOIDAL TEAR, LBS ASTM-D-4533 74 LBS
TD TRAPAZOIDAL TEAR, LBS ASTM-D-4533 66 LBS
UV RESISTENCE, % SR ASTM-D-4355 80% @ 500 HOURS
AOS, US SIEVE # ASTM-D-4751 40
PERMITTIVITY (1/SEC) GAL/MIN/SQ.FT ASTM-D-4491 .20 (S-1)
FLOW RATE ASTM-D-4491 12.5 GAL/MIN.FT2



NON-WOVEN FABRIC SPECIFICATIONS
PROPERTY TEST METHOD MINIMUM ROLL / AVERAGE VALUE
GRAB TENSILE ASTM-D4632 140 LBS
GRAB ELONGATION ASTM-D4632 50%
TRAPEZOID TEAR ASTM-D4533 58 LBS
PUNCTURE RESISTANCE ASTM-D4833 80 LBS
PERMITTIVITY ASTM-D4491 17 SEC-1
WATER FLOW ASTM-D4491 115 GPM/FT2
A.O.S ASTM-D4751 70 U.S. SIEVE
U.V. RESISTENCE ASTM-D4355 70%/500 HRS

 